There is a problem with the coil issue. When rotating in the start
mode, the magnet field. will not create enough voltage to excite the
circuit so the spark will not jump the gap at compression pressure.
Therefore, a coil needs to be wound with many extra turns in order to
solve the starting problem. However, the magnet field when turning at
high speed, will over heat a coil that is wound for starting
purposes. The Revmaster coils are wound for high speed (3500 rpm)
and are not capable of producing sufficient voltage in the start
mode. In order to solve this start and high speed problem, the
circuitry incorporates a transformer which boosts the voltage during
starting only. Once the starter is disengaged, the transformer is out
of the circuit. For your high speed application of 5000 rpm, depending
on the magnet field, it would require coils that are special wound. I
suggest that you contact Al D'Alo at A.R.D. Engineering,
562-863-8362. He winds our coils for the Revmaster CDI system.
Thanks Joe.
Paul Lamar
--