It is sometimes difficult to mount fuel pumps in AC wings.
Most people don't do it. They mount the pumps on the firewall.
Paul Lamar
Paul,
I'm just starting construction of my fuel tanks for a Zenith CH-640.
I'm opting for a four wing tank system. I'll likely be using a 16b
conversion,
fuel injection based on your designs. With the discussion on-going
about
in tank fuel pumps and fuel return lines, I am asking if I need to make
accomodation for anything special. Presently, my tanks have no
provision for
a fuel return or in tank pump. Would it be necessary to design in any
of this stuff?
Thanks, C. Smith
Yes you might think of adding a large removable panel in the root
ribs for internal pumps. The 640 has a nice thick wing for internal
pumps. Looks like the tanks are in the leading edge. If not
practical use two lines from each tank. One for feed according
to the plans and one for return fuel.
Paul Lamar
Correction, I meant 13b engine.
C. Smith--
So the EFI system with a fuel return line would preclude the use of a
fuel flow meter to keep track of fuel used and burn, unless someone
knows of a meter that subtracts the return flow?
so with a 4 tank system, thats 8 fuel lines, and a tank selector valve
ganged 4x4? 4 separate fuel pumps, and control wiring?
No other way to do this? I'm bummin' out.
C Smith
C,
There are systems that will subtract the fuel return, but dont bother.
Here is what I recommend.It is what I did an I find it works very well.
Route your SINGLE return line to a tank you consider your 'main' tank.
Not a header, but your largest tank.The fuel valve now has to select
only which tank you are drawing from, but you will obviously be using
your main tank most of the time.When you select one of the other
tanks, the fuel then is in essence being transferred to the main tank.
That is OK.Will transfer at a known rate of about a gallon/min.It is
imperative that you set some sort of alarm to avoid overflowing the main
tank.I actually have a fuel flow transducer on my RETURN line, and I
set it to remind me after I have transferred the desired number of
gallons to the main tank.
This is simple and reliable.Only one simple return line, simple fuel
select valve, and only necessitates an alarm for when using one of the
other tanks.
As a fuel totalizer, use something that tallies the injector workload
such as Ed Anderson's EFI monitor or Tracy Crooks EM2.I have Ed's and
it does a very accurate job of keeping track of the fuel.
JMHO
--
David Leonard
Turbo Rotary RV-6 N4VY
http://N4VY.RotaryRoster.net
http://RotaryRoster.net
I think I will build this simple circuit on to the 555 injector PC
board. All you will need is a digital voltmeter for read out of GPH.
Paul Lamar
--
The Rotary Engine NewsLetter. Powered by Linux.
ACRE NL web site.
http://www.rotaryeng.net
Youtube key word UTUBPLEASE
Copyright 1998-2008 All world wide rights reserved.