There are systems that will subtract the fuel return, but dont
bother. Here
is what I recommend. It is what I did an I find it works very well.
Route your SINGLE return line to a tank you consider your 'main'
tank. Not
a headder, but your largest tank. The fuel valve now has to select
only
which tank you are drawing from, but you will obviously be using
your main
tank most of the time. When you select one of the other tanks, the
fuel
then is in essence being transferred to the main tank. That is OK.
Will
transfer at a known rate of about a gallon/min. It is imperative
that you
set some sort of alarm to avoid overflowing the main tank. I
actually have
a fuel flow transducer on my RETURN line, and I set it to remind me
after I
have transferred the desired number of gallons to the main tank.
This is simple and reliable. Only one simple return line, simple fuel
select valve, and only necessitates an alarm for when using one of
the other
tanks.
As a fuel totalizer, use something that tallies the injector
workload such
as Ed Anderson's EFI monitor or Tracy Crooks EM2. I have Ed's and
it does a
very accurat job of keeping track of the fuel.
JMHO
--
David Leonard
Dave -
First:
Thanks for screwing up my "simple" PWM EFI fuel pump plans. Now I
have to return something, somewhere, somehow. I'm still working on
the PWM project though.
Second:
One of the best all-electric solutions I've considered for your
(damned) return line is to use 2 solenoids after the "T" for the
return - one left, one right. The left & right electric switches
control which EFI pump is powered, AND which solenoid opens to allow
returned fuel to flow to the respective tank. More parts, more amps.
Is it still worth it? I'm gonna find out.
In all seriousness, I don't think the PWM controlled EFI fuel pump is
going to be worth the effort & complexity unless used in a RETURN-LESS
system.
However, I want to address the issues you brought up earlier. The PWM
EFI system fuel rail can have a return to the main tank with a simple
inline ball valve. This will be used to purge contaminants and vapors
when necessary. Otherwise it is essentially a return-less system.
Simple. Reliable.
What are your thoughts?
-Vince Orton
Hi Vince,
Can your "returnless" PWM system have a return line.....of sorts. Since
the purpose of the return is only to "burp" the system, you need to pass
air or gas bubbles. Copper tubing for refrigeration purposes is
available in very small inside diameters. On the order of .020 to .040, and
in
lengths to 20 feet. The idea in refrigeration is a combination of dia and
length
yields a known restriction the freon must pass thru. If a size and
length could be chosen to pass "air" and gasoline at an extreemly small
rate--say a pint an hour at max system pressure-- the return line could be
routed
to any tank. A four hour flight would then put an additional HALF gallon
into a tank, likewise on that four hour flight your "in use" tank would be
short a half gallon. Flying to envelop limits that are going to be hindered
by
a half gallon over a four hour flight is just not prudent anyway.
Dave M
Is it necessary for a cut-off valve for each tank? I was thinking of
feeding a header tank, with a cut-off valve to the engine, by gravity
from the the wing tanks and have a return line to one of the wing tanks.
Pierre
South Africa
And what is the reasoning for returning the fuel to a "main" tank rather
than the header. If you return the fuel from the fuel rail, of course the fuel
will be hotter, however if it is returned from just after the pumps, it will
be essentially the same temperature (save a little compression heat rise)?
Rich
--
The Rotary Engine NewsLetter. Powered by Linux.
ACRE NL web site.
http://www.rotaryeng.net
Youtube key word UTUBPLEASE
Copyright 1998-2008 All world wide rights reserved.