Paul
The temperature compensation was only an idea.
Not a good one as it turns out.
Ah ha, just, re-read your comment.
Obvious---the pot alters the mixture proportionally to 555 increasing or
decreasing the pulse width across the whole range.
The temp sensor is another input, hence the need for computamebobs,
that we
don't want.
Here's another idea (so don't shoot me if no good)
Could the MAP output be also used to drive a PFM for the fuel pump?
Someone was working on that a while back.
Clive.
Yes I think that could be made to work. However I, like Dave Leonard
prefer
a
full return system for several reasons. One of which it is known to work.
-------------------------------------------------------------------------
I have given this a bit more thought since Clive mentioned it again.
One 555 with input from a crank angle sensor and manifold pressure might
work.
It looks like one of the cheapest fuel injection systems of all as you
need
the fuel pump anyway. The fuel injected is both pulse width modulated by
manifold pressure and proportional to engine RPM by pulse rate. It is the
product of RPM and manifold pressure. Easy to check on the bench as
all you
need is a hand vacuum pump to simulate manifold pressure and a pulse
generator to simulate the crank angle sensor.
One problems is controlling the power supply voltage to the fuel pump.
The
voltage regulator in most alternators maintain the supply at 13.9
volts more
or less which may be sufficient.
The simple mechanical passive injectors themselves are available in a
wide
variety from Kinsler.
http://www.kinsler.com/page--Home-Page--13.html
------------------------------------------------------
More info on the size of the injector orifice to try. The rotary has one
large advantage here as one injector in effect services two cylinders
in an
equivalent 4 cylinder engine. This means they can be twice the area.
Paul Lamar
Hi Paul
That sure would be a simple system.
555 PWM RPM/MAP controlled fuel pump constant flow injectors.
No return plumbing.
Fully redundant system:-
2 x 555 controllers
2 x pumps
2x leaning rheostats
1 x Control divider
1 x on/off/on switch.
As many or few injectors as you want. (If you want to be really cheap a
spray tube would probably work upstream)
I don't think the 13.9 volts is a problem as Kinsler market the Weldon
"Dial-A-Flow" PWM fuel pump controller that does the same job without the
RPM controlled element, so no good in this application, its $400 (ouch).
It can be found on page 130 of the Kinsler 2008 catalogue link provided
below. They list pages 124-129 for suitable pumps to use and it's a big
list.
RPM and load sensing, so suitable for turbos and wobbly props???
Clive
There is no reason to expect the fuel pump output volume would have a
linear relationship with the input voltage. You will need to detect the
pump output and compare it to the integrated 555 output to drive the
pump. If the pump is a positive displacement type you can use the pump
RPM as a signal for comparison, otherwise you need a flowmeter turbine
or pressure sensor.
Victor Roberts
You have a point there. I'll find out when I bench test it.
The one I have is positive displacement.
---------------------------------------------
Here is some data from Kinsler on the subject.
They have the output pressure constant at 40 psi which will not happen in the
real world however it is not that far off linear in this range. It might work.
Paul Lamar
--
The Rotary Engine NewsLetter. Powered by Linux.
ACRE NL web site.
http://www.rotaryeng.net
Youtube key word UTUBPLEASE