Linux can cut and paste out of pdf files but
I am not sure that is possible in windows.
In an event it is a good idea to get the programming docs
out of the pdf and into text form so you can cut and paste
comments and commands directly into your program.
Here is a PWM example.
******************************************************************************
OpenPWM
Type Subroutine
Invocation OpenPWM(channel, frequency, mode)
OpenPWM(channel, frequency, mode, stat)
Parameter Method Type Description
channel ByVal Byte The channel to use for PWM generation.
frequency ByVal Single The desired PWM frequency.
mode ByVal Byte The desired PWM mode (see discussion below).
stat ByRef Boolean The variable to receive the status code.
Discussion
This subroutine prepares a PWM channel for generating a
pulse width modulated (PWM) signal. PWM
generation is performed using one of the CPU’s 16-bit
timers, the number of which varies depending on
the ZX model. The table below indicates the available
channels and the corresponding timer used. See
the description of PWM() for additional details on the PWM
channels.
Supported 16-bit PWM Channels
ZX Models ....... Timer1 Timer3 Timer4 Timer5
ZX-1280, ZX-1280n 1, 2, 3 4, 5, 6 7, 8, 9 10, 11, 12
The frequency parameter specifies the PWM base frequency in
Hertz. Since the same frequency and generation mode will
be used for all PWM channels based on the same timer, it is
only necessary to call OpenPWM() once to prepare the timer
for all of the PWM channels that are based on a given
timer.
The mode parameter specifies the PWM generation
mode. Two modes are supported: Fast PWM mode and
Phase/Frequency Correct mode. The constants zxFastPWM and
zxCorrectPWM, having the values 0 and 1 respectively, may
be used to specify the mode.
The Fast PWM mode has a
maximum frequency of one-half of the CPU clock frequency
and is intended for fixed-frequency applications. The
Phase/Frequency Correct PWM mode has a maximum frequency of
one-quarter of the CPU clock frequency and may be used when
the PWM frequency will be changed in the midst of PWM
signal generation.
Frequency changes are effected by
making additional calls to OpenPWM() and the change is
synchronized so that it takes effect at the beginning of a
cycle. The status parameter, if supplied, receives a value
to indicate success or failure of the call. A side effect
of calling OpenPWM() is that the timer busy flag for the
underlying timer (e.g.
Register.Timer1Busy) will be set to
True irrespective of its prior state. It is recommended
that the initial call to OpenPWM() be preceded by a call to
acquire the semaphore for the timer. This will ensure that
an existing timer operation will not be disturbed.
Example
Call OpenPWM(1, 50.0, zxFastPWM)
'prepare for 50Hz Fast PWM using channel 1
Compatibility
This subroutine is not available in BasicX compatibility mode.
See Also ClosePWM, PWM
Paul Lamar
--
The Rotary Engine NewsLetter. Powered by Linux.
ACRE NL web site.
http://www.rotaryeng.net
Youtube key word PaulLamar2