Scroll down to to the bottom Steve.
We do everything in chronological order.
Paul
This is a homebuilt MSD system with one spark
every 10 degrees starting at 20 degrees BTDC.
400 watts ought to be plenty. No guarantee on
spark plug life however. Try iridium.
I need to update 555 crank angle sensor 3 dwg to show
more HE sensors.
Paul Lamar
Paul,
I like the design. If I understand correctly, a 3-rotor would take three
of the units shown in your drawing, "High-Voltage half bridge
driver.jpg".
And there would be three inverters required also? Nice for redundancy,
but a
bit on the heavy side. What about the trailing plugs?
Mark
A three rotor would not need three units. Just one. The stationary
disk is printed circuit board material with 3 groups of hall efect
sensors equal spaced at 120 degrees. Starting at 20 degrees BTDC
the HE's would then be at 10 BTDC, TDC, 10 ATDC and 20 ATDC.
Then for a 3 rotor the HE pattern would be repeated 120 degrees later.
snips...
Paul,
I understand the groups of HE's spaced 120* apart, but I don't see how the
system knows which coil to fire. Please explain.
Mark
This schematic is for a one rotor engine with one
coil and one spark plug.
Each plug has its own coil. Each HE has its own capacitor discharge
system. All four HE/CD's fire the one coil. For every coil there
are four HE/CD systems. Sounds complicated but the CD systems
and HE's are cheap. The CD system mostly uses tiny little 8 pin
dips. What keeps the overall cost down is the 220 volt power supply
common to six HE/CD systems.
For your 3 rotor engine you would need six of these systems, six coils
and one 220 volt power supply. Two per rotor. One for leading
plugs and one for trailing plugs. Of course you could put a reduced
capability, entirely different, less powerful system, on the trailing
plugs. Just to keep you flying.
If desired, for a bit more redundancy, you could use two power supplies.
One for all the leading plugs and another for all the trailing plugs.
You can also split the timing by moving the trailing HE's on the printed
circuit board.
Also re read:
http://www.rotaryeng.net/Why-CDI.html
I expect this system to put out a bit more power
with a lower BSFC. In other words the same power
with a lower fuel burn.
Paul Lamar
OK, so then you would need multiple units. That makes sense now.
Mark
It is the only way to be sure all the capacitors are fully
charged at high RPM.
Paul Lamar
Hi guys,
I'm coming into this quite late, and don't have all of the background info.
I don't know why it is thought that three Hall-effect sensors are required,
as if you have a flywheel with a ring gear, a pair of Hall-effect sensors
will do.
One Hall sensor gives a signal to indicate absolute position of the rotors;
say for example 50° BTDC on rotor 1.
Another Hall sensor counts flywheel teeth, acting as a clock input to a
microcontroller that keeps track of how many degrees the engine has turned
since the 50°BTDC input has occurred.
The engine RPM can also be determined by the flywheel tooth counter input -
or the absolute position input, whichever you prefer.
Steve in Orlando
Steve We are using a unusual micro controller that does not do counting
well. Check out AVR ZBasic 1280n. The up side is it is 10 times
easier to program. We trade off hardware for software.
Rotary engines are super simple so no counting of teeth is needed.
Just use another $1 HE as the rotors fire 180 out of phase once per RPM.
Paul Lamar
--
The Rotary Engine NewsLetter. Powered by Linux.
ACRE NL web site.
http://www.rotaryeng.net
Youtube key word PaulLamar2
Copyright 1998-2010 All world wide rights reserved.