Subject: Ignition timing turbo charged rotary engines.
From: Rotary Engine
Date: 11/14/2010, 10:04 AM
To: AAA Put this in the To box

Does the attached ignition timing map look about right, at least as a
starting point?

And are the positive numbers BTDC?


Jay

Yes the positive numbers are BTDC.
Sounds like the negative numbers are ATDC.

What rotary engine are you using and what turbo charger
are you using?

What kind of computer are you using?
Are the manifold pressure numbers in inches of Hg?
They appear to be.


Paul Lamar


That ignition ignition advance chart is just an example I found on the net.
I was just looking for a good starting point.

To answer your questions.

20B CXRacing T-76 P trim, 1.15 A/R turbine, oil and water cooled
Tracy Crooks EC3

I'm mostly waiting on my custom headers after which I'll be
doing a test run soon on a stand.

Jay

I am not sure that ignition advance chart will do you much good.
Does anybody running Tracy system know how to change the ignition
advance curve?

I would install a turbocharger tachometer kit from Garrett.
You don't want to destroy your turbo charger and risk your
life  by allowing it to over rev. Many people have been there
and done that so far including Mistral.

Most automotive turbo charger
set ups have turbines that are overly powerful for good
boost ramp up but they will over speed when run at continuous
power levels found in aircraft engines. Especially at 8000
feet and above where the atmospheric back pressure is lower
on the turbine.

This is particularly important on the rotary where
the exhaust gas temperature could be as high as 1800 F.
This high temperature drastically lowers the strength
of the turbine blades.

Paul Lamar
-- 
The Rotary Engine NewsLetter. Powered by Linux.