Suppose one has a supposed 24v alt installed on a 12v system, with an old
Ford type Cessna 12v regulator. The voltmeter in the plane (several of
them)
never indicates over 14 or so volts. Will a regulator limit the voltage
delivered to no more than 12-14v or ? What would supposedly happen if
a REAL
24v alt were installed-I'm thinking all sorts of mayhem-battery, bulbs,
kaput 12v radios, etc? We are talking 60A unit here. Inquiring minds
want to
know....(I think I have a mislabeled OEM unit!)
Marc W
The regulator will control the output. At low loads, many alternators
rated at 14 volts can put out over 50 volts if the regulator fails. That
is why most certificated installations have an external regulator and
also have a separate over-voltage circuit which can disable the
alternator if the regulator fails. A 28 volt alternator with external
regulator can be used on a 14 volt system but it may fail to put out
it's rated current, because the internal magnetic field used to generate
the current is less than it would be with a 28 volt excitation.