Suppose one has a supposed 24v alt installed on a 12v system, with an old
Ford type Cessna 12v regulator. The voltmeter in the plane (several of
them)
never indicates over 14 or so volts. Will a regulator limit the voltage
delivered to no more than 12-14v or ? What would supposedly happen if a
REAL
24v alt were installed-I'm thinking all sorts of mayhem-battery, bulbs,
kaput 12v radios, etc? We are talking 60A unit here. Inquiring minds want
to
know....(I think I have a mislabeled OEM unit!)

Marc W


Marc,
one of the more popular small alternators (B&C-20)  for the continental uses
the same alternator for both 14 and 28v and only the regulator is changed.
Larry

Perfect example. That's a wound field alternator.

The regulator will just lower the field current until the output voltage is in
the right range.

Matt


     There are two versions of the B&C-20, one is wound for 14V  another is wound for
28V.    Regulator is external.  Different alternators,
different regulators.

One way to check your alternator.  Energize the field, and hook up a bank of
power resistors to handle the load. Spin up the alternator
and see if it can put out 30V @ 10Amp load. If so, that is a 24V unit.    With
two units side by side you'll see the wiring size difference,
pretty hard for a shop to mix them up during a rebuild.

Regulators are on/off.  Early ones used relays to control the field,  later
semiconductor versions also use the same on/off principle.  Nothing fancy
about it.

Tom W



-- 