Subject: futher noodling of the EFI fuel system
From: Rotary Engine
Date: 11/22/2010, 3:39 PM
To: AAA Put this in the To box



Hello Paul,

OK, so I have a high wing configuration plane with two tanks in each wing.  Each is plumbed independently.

If I set up two on/off valves, one for outboard (both tanks) and one for inboard (both tanks)and have the valves drop the still gravity fed fuel into a header tank (which would of necessity "vent" back to the two selected tanks); if I then have the header tank feed the high pressure fuel pump and have the return (still under pressure from the pump) line feed trough a check valve back into the header tank, fuel would return to whichever set of tanks was selected, wouldn't it?  I guess that assumes that the pressure from the pump would exceed the gravitational pressure and be able to put fuel into the header.  Is that doable?

It looks like the simplest fuel management I can do if I cannot return fuel directly to the tank from which it is derived.  I'm not sure I have space for four fuel lines per side going up the cabin side channel, nor are the wings plumbed for return lines, at present.  Even if I did, I'd have to have four valves instead of two.  Thoughts?

Thanks,

William Hagood


I would have to do a 3D on this so I can picture the complete system.
It is hard to picture this in my mind. Hang on and  I'll do a 3D shortly.

BTW you can link together 2 much cheaper tank selector valves
so they both move at the same time.


Paul Lamar
-- 
The Rotary Engine NewsLetter. Powered by Linux.
ACRE NL web site. http://www.rotaryeng.net
Youtube key word PaulLamar2
Copyright 1998-2010 All world wide rights reserved.