Subject: futher noodling of the EFI fuel system
From: Rotary Engine
Date: 11/24/2010, 2:57 AM
To: AAA Put this in the To box



   Hello Paul,

 OK, so I have a high wing configuration plane with two tanks in each wing.  Each
 is plumbed independently.
  If I set up two on/off valves, one for outboard (both tanks) and one for inboard
 (both tanks)and have the valves drop the still gravity fed fuel into a header
 tank (which would of necessity "vent" back to the two selected tanks); if I then
 have the header tank feed the high pressure fuel pump and have the return (still
 under pressure from the pump) line feed trough a check valve back into the
 header tank, fuel would return to whichever set of tanks was selected, wouldn't
 it?  I guess that assumes that the pressure from the pump would exceed the
 gravitational pressure and be able to put fuel into the header.  Is that doable?
  It looks like the simplest fuel management I can do if I cannot return fuel
 directly to the tank from which it is derived.  I'm not sure I have space for
 four fuel lines per side going up the cabin side channel, nor are the wings
 plumbed for return lines, at present.  Even if I did, I'd have to have four
 valves instead of two.  Thoughts?
  Thanks,
  William Hagood

   I would have to do a 3D on this so I can picture the complete system.
 It is hard to picture this in my mind. Hang on and  I'll do a 3D shortly.
  BTW you can link together 2 much cheaper tank selector valves
 so they both move at the same time.
   Paul Lamar

 I've been looking at stacking valves.  And I think I can keep it to two valves
  (matches my IQ) so fuel management is simple-- one inboard and one outboard.  Do
  I need to vent the header tank separately if back flow to the tanks of origin is
  unimpeded (i.e. no check valves)?  Seems like venting to top of cowl would still
  be below tanks and permit siphoning.
 I'm not big on having fuel in the cockpit with me but opening and re-plumbing
  wings sounds dreadful.
 Thanks,
 William Hagood
 Venting to the top of the cowl only applies to the Glass Goose.
  What kind of airplane do you have?
 Paul Lamar
 I'm building a Zenith 801.

 William Hagood

 Good choice. With 250 HP that will really be short take off :)
 I would put a brake on the nose gear and it will become really short
 landing as well.

 A cowl sump tank gravity fed by both wing tanks is very simple as long as you
 run the header tank vent back up into the wing and out to one tip. Or you could
 run the header tank vent line back to the tail and up to the top of the vertical
 stab. High wings are simple.

 The return flow from the EFI can go to the header tank.
 However the shape of the header tank is important. Assuming it is
 the width of the cockpit It should have a deep pyramid shaped bottom
 to insure the pump pick up is never un-covered in a side slip or power
 on stall. This is less of a problem if the header tank is narrow and
 only one or two gallons.

 You can run one way flapper valves from the outer wing tanks to the inner wing
 tanks. Vent the outer tanks to the wing tips and point the vents straight out
 or back. Use one way valves on the outer tank vents to insure you do no lose
 fuel out the vents in an un coordinated turn or side slips. If the tanks are
 full and the airplane sits in the hot sun the fuel will expand and be forced
 down into the header tank and back out the header tank vent.

 Paul Lamar


 Thanks all.  I'll keep plugging away.

 William Hagood
 LexAmi


Paul / William,
I have the same airplane and faced the same decision. I chose to route all
bypass fuel back to the right wing tank, regardless of which tank is selected. KISS.

Pro's
1. Fewest number of interconnects and parts, moving or otherwise (one continuous
line from FW to wing root)
2. No chance of heated fuel recirculating as is possible in a header tank

Con's
1. Opportunity to overflow fuel in the right tank, requiring pilot monitoring &
tank management.

I labeled my right tank selection with "USE FOR GROUND OPNS", as taxi / idle has
the highest bypass fuel rate and most likely both tanks will be full, resulting
in spillover. After that just alternate.

--KA

Kenneth,

Did you use metal or rubber lines up the cabin sides?  I haven't finished the forward fuselage.  I am guessing there are significant clearance issues.  Are your outboard tanks plumbed to the mains or are they plumbed independently?

Paul,  if the header is a vertical 1-2 gal. cylinder, does that minimize the risk of an uncovered pickup?

William Hagood

Yes it does. These EFI engines stop in a micro second if not sooner when fuel pick up is interrupted. That is why a "both" fuel valve is a no no on
a low wing airplane.

Paul Lamar
-- 
The Rotary Engine NewsLetter. Powered by Linux.
ACRE NL web site. http://www.rotaryeng.net
Youtube key word PaulLamar2
Copyright 1998-2010 All world wide rights reserved.