Hello Paul,
OK, so I have a high wing configuration plane with two tanks in each wing. Each
is plumbed independently.
If I set up two on/off valves, one for outboard (both tanks) and one for
inboard
(both tanks)and have the valves drop the still gravity fed fuel into a header
tank (which would of necessity "vent" back to the two selected tanks); if I then
have the header tank feed the high pressure fuel pump and have the return (still
under pressure from the pump) line feed trough a check valve back into the
header tank, fuel would return to whichever set of tanks was selected, wouldn't
it? I guess that assumes that the pressure from the pump would exceed the
gravitational pressure and be able to put fuel into the header. Is that doable?
It looks like the simplest fuel management I can do if I cannot return fuel
directly to the tank from which it is derived. I'm not sure I have space for
four fuel lines per side going up the cabin side channel, nor are the wings
plumbed for return lines, at present. Even if I did, I'd have to have four
valves instead of two. Thoughts?
Thanks,
William Hagood
I would have to do a 3D on this so I can picture the complete system.
It is hard to picture this in my mind. Hang on and I'll do a 3D shortly.
BTW you can link together 2 much cheaper tank selector valves
so they both move at the same time.
Paul Lamar
I've been looking at stacking valves. And I think I can keep it to two valves
(matches my IQ) so fuel management is simple-- one inboard and one
outboard. Do
I need to vent the header tank separately if back flow to the tanks of
origin is
unimpeded (i.e. no check valves)? Seems like venting to top of cowl would
still
be below tanks and permit siphoning.
I'm not big on having fuel in the cockpit with me but opening and re-plumbing
wings sounds dreadful.
Thanks,
William Hagood
Venting to the top of the cowl only applies to the Glass Goose.
What kind of airplane do you have?
Paul Lamar
I'm building a Zenith 801.
William Hagood
Good choice. With 250 HP that will really be short take off :)
I would put a brake on the nose gear and it will become really short
landing as well.
A cowl sump tank gravity fed by both wing tanks is very simple as long as you
run the header tank vent back up into the wing and out to one tip. Or you could
run the header tank vent line back to the tail and up to the top of the vertical
stab. High wings are simple.
The return flow from the EFI can go to the header tank.
However the shape of the header tank is important. Assuming it is
the width of the cockpit It should have a deep pyramid shaped bottom
to insure the pump pick up is never un-covered in a side slip or power
on stall. This is less of a problem if the header tank is narrow and
only one or two gallons.
You can run one way flapper valves from the outer wing tanks to the inner wing
tanks. Vent the outer tanks to the wing tips and point the vents straight out
or back. Use one way valves on the outer tank vents to insure you do no lose
fuel out the vents in an un coordinated turn or side slips. If the tanks are
full and the airplane sits in the hot sun the fuel will expand and be forced
down into the header tank and back out the header tank vent.
Paul Lamar
Thanks all. I'll keep plugging away.
William Hagood
LexAmi
Paul / William,
I have the same airplane and faced the same decision. I chose to route all
bypass fuel back to the right wing tank, regardless of which tank is selected.
KISS.
Pro's
1. Fewest number of interconnects and parts, moving or otherwise (one continuous
line from FW to wing root)
2. No chance of heated fuel recirculating as is possible in a header tank
Con's
1. Opportunity to overflow fuel in the right tank, requiring pilot monitoring &
tank management.
I labeled my right tank selection with "USE FOR GROUND OPNS", as taxi / idle has
the highest bypass fuel rate and most likely both tanks will be full, resulting
in spillover. After that just alternate.
--KA
Kenneth,
Did you use metal or rubber lines up the cabin sides? I haven't finished the
forward fuselage. I am guessing there are significant clearance issues. Are
your outboard tanks plumbed to the mains or are they plumbed independently?
Paul, if the header is a vertical 1-2 gal. cylinder, does that minimize the
risk of an uncovered pickup?
William Hagood
Yes it does. These EFI engines stop in a micro second if not sooner when fuel
pick up is interrupted. That is why a "both" fuel valve is a no no on
a low wing airplane.
Paul Lamar
In selecting a fuel pump, what pressure output do I need?
William Hagood
Carb or EFI? EFI 60 psi. Carb 15 psi.
Paul Lamar
--
The Rotary Engine NewsLetter. Powered by Linux.
ACRE NL web site.
http://www.rotaryeng.net
Youtube key word PaulLamar2
Copyright 1998-2010 All world wide rights reserved.