Subject: Tracy's EC 2 computer
From: Rotary Engine
Date: 1/22/2011, 10:08 AM
To: AAA Put this in the To box



    How may people have wired an EC2?
    How many people need to wire an EC2?
    How many people have wired it more than once?

    Paul Lamar
    --

   0
   1
   0
   In our household.

   John

   I still have to wire mine.  Not looking forward to it, I was
   planning on buying a wiring harness from Bob but I never got around
   to it.

   Mike C

   Paul


I will recommend this company again...  Igus is a German company with
offices in RI.   They will sell machine and data cable with no cut charge
and no minimum.  I used their CF240-xx-xx shielded cable to wire
Tracys EM2 and EC3 for my Subie pusher. I would recommend 22ga or
heavier for ease of use, you can get from 3 to 24 conductors, all color
coded.
I also used their mil spec 4 gauge for battery cables.  I didn't price
single
conductor 16ga wire, instead ordering from SkyGeek (100 ft minimum).

The best part is that this is mil spec teflon cover which conforms to FAA
recommendations (no toxic smoke if there is a fire).  And the price wasn't
bad either, my 14 conductor was less than $2 per foot in 2009.

Yes I am also working on a single rotor for future planes *:*D

Igus, Inc
1-800-521-2747

Mike C I will build if you wish (but it won;t be inexpensive!!)

Dan F

Their web site is unfathomable.

What is all this stuff? They need to speak english :)
http://www.igus.com/iPro/iPro_01_0013_0074_USen.htm?c=US&l=en

I have no idea what they are talking about.

-----------------------------------------------------------------------
Conductors: Conductor consisting of a highly flexible special alloy
Conductor insulation: Mechanically high-quality TPE mixture
Conductor twisting: Conductors stranded in one layer with especially short pitch length.
Conductor colors: In accordance with DIN 47100.
Inner Jacket: TPE
Shield: Alloy strand braid, coverage approx. 90% optical
Outer jacket: Low-adhesion mixture on the basis of TPE. Especially abrasion-resistant and highly flexible. Silicon-free in compliance with PV 3.10.7 - status 1992. Color: dark blue (RAL 5011).

Technical Data

Minimum bending radius, moving: 4 x outer cable diameter
Minimum bending radius, fixed: 3 x outer cable diameter
Permissible temperature, moving: -31°F to +194°F (-35°C to +90°C)
Permissible temperature, fixed: -40°F to +194°F (-40°C to +90°C)
UV-resistance: High
Oil-resistance: High
Voltage: 300V
Testing voltage: 1500 V
Regulations: CE, RoHS: 2002/95/EC
Typical application areas
Typical Applications

   * for maximum load requirements at 4 x d
   * indoor and outdoor applications
   * especially for short, very fast applications with small radii and tight design space
   * automatic insertion machines. automatic doors, cleanroom, very quick handling, low temperature locations
-----------------------------------------------------
Paul Lamar

-- 
The Rotary Engine NewsLetter. Powered by Linux.
ACRE NL web site. http://www.rotaryeng.net
Youtube key word PaulLamar2