Subject: 2nd gen turbo charger cooling system.
From: Rotary Engine
Date: 3/14/2011, 6:40 PM
To: AAA Put this in the To box


I was in the process of rebuilding the oil supply
   and turbo  water cooling system on the 2nd gen Mazda turbo
charger.   Cooling the turbo shaft has a large effect on the
strength   of the turbine blades. See the JPG. The highest stress is
at   the root of the blades attached to the shaft. If one can cool
the shaft one can strengthen the joint.

I had redesigned the intake manifold, made casting patterns in
a stereo lithography machine at the local college and had castings
made and machined. We sold out except for the one I saved for the
turbo engine in my KIS cruiser kit. We could not use the original
turbo intake manifold as it was too high for the low KIS cowl. In
fact it was not a good idea to use it cut down as it gave a rather
bad aerodynamic internal shape. Unfortunately, or fortunately
depending on how one looks at it, we lost the turbo cooling water
connection when we redesigned the manifold. I did not think too much
about it until recently when it became necessary to redesign the
cooling system.
I was stunned to find out the cooling water going to the turbo was
  already
heated by the hottest part of the engine. That reduced the cooling
effect on the turbo. The second stunning fact was the turbo
cooling   water drain back did not go to the flow of hot water going
into the   rad to be cooled yet again as one would think. It short circuited
the rad and flowed back into the input side to the water pump
along   with the cool water from the rad!!!
What the heck were the Mazda engineers thinking??? This means the
heat put into the turbo cooling water was now heating the engine
cooling water before it got into the engine and do its job of
cooling the engine???? No wonder it was so hard to cool the turbo
engine as Dave Leonard found out. He had to use a really thick rad.
IMHO It would be much better to send the turbo cooling water to
the   rad along with the hot water from the engine. That would increase
the temperature of the rad increasing the heat transfer to the out
side cooling air. That would supply colder water to both the
engine   and the turbo.
IMHO this stock turbo cooling system is partially to blame for all
the stock turbo failures we have seen.
What am I missing?
This also has implications for the turbo compound version that
uses   a turbo charger.
Paul Lamar
Paul,
There may be a couple of things involved.
1: Maybe they were thinking about after shutdown thermosyphon to
cool the  turbo. The shorter distances give less resistance to the
flow helping to  increase the flow rate.
2: Having the return going directly into the water pump suction
line  will give  the highest differential pressure across the turbo
which should help  increase  the flow through the turbo while running.
I do have to agree the heated water coming out of the engine does not
  seem to
  make sense. Possibly the temp of the turbo makes the inlet coolant
  temp not
  important. It does look like the plumbing is short in Mazda's
version. A  redesign seems to be in order. For automotive use it is
likely not  extremely  important but for an engine that will run for
hours at 75% max power,  it is  looking mandatory.
Dale Davies
1: I guess that is a possibility but that sounds too sophisticated.
2: What do you think of sourcing  the cool water out of the outlet
  side of the pump and returning to the hot side of the rad?
The water out of the block is close to steam temperature to begin
  with. I think steam is coming out of the turbo, as it runs 400 F or
  higher around the bearings.
Paul Lamar

Do you think that Mazda was looking at bringing the engine up to
operating temp as quickly as possible utilizing heat from the turbo?
As stated, automotive applications rarely tap sustained power for
more than several seconds.

rog

That is the best reason I have heard so far. Smog is a large issue
for car engines so that would cut emissions.

Thanks rog.

Paul Lamar/


Rog's notion may be part of it all right. For AC use I would definitely pull
the cool coolant from the water pump outlet and return to the hot radiator
side to try to lower the turbo temp and get as good a flow through the turbo
as possible. At that turbo temp, a few degrees cooler in to it may not be much
help. A normal running automotive engine ( and most industrial engines) with a
thermostat operate with a temperature differential across the radiator of
about 10 to at most 15 degrees F. I wonder how a second cooling system just
for the turbo would work. It would involve extra weight and using a second
water pump. I think you could get away with using an electric pump just for
the turbo.

Dale Davies

We are going to increase the water and oil flow as well.
Cars are only making 40 to 50 HP on average. The turbo only sees
momentary use in a car.

Paul Lamar

-- 
The Rotary Engine NewsLetter. Powered by Linux.
ACRE NL web site. http://www.rotaryeng.net
Youtube key word PaulLamar2
Copyright 1998-2011 All world wide rights reserved.