If you still have the gear as part of the front stack rather than a
spacer, just drop in a CAS and give it a try. I have no idea if
polarity affects CAS pickups, but my home built crank trigger using
Chrysler pick ups were affected by polarity. A positive going pulse
had a nice flat front on it to trip the SCR but when reversed, the
long slow build of the positive side had timing going nuts. Just
switching the hookup wires got everything working fine.
Lynn E. Hanover
Well this could definitely be my problem. My engine was a salvaged
Japanese domestic engine from a car which had been in an accident,
evidently a front- ender. I pulled apart the engine and everything was
fine except for the fact that one of the CAS connector plugs was
damaged and there was a small hole in the front cover which I welded
up. So, I'm not absolutely sure that in fact I wired them up
correctly. Given that there are two sensors with two leads each, and
there is a common lead going to both sensors, there are four possible
configurations for the wiring. so I have a 25% chance that I have it
right.
Ib a similar note, does anyone know where I might find the proper CAS
connectors for the 93 13BREW?
Brian Trubee
Those are not hall effect sensor. They are called VR or variable
reluctance
sensors. You will need a high speed scope to look at the wave form.
Down load the shop manual for the 93.
http://foxed.ca/foxed/index.php?page=rx7manual
The shop manual shows only 4 wires.
Paul Lamar
Ok, they are variable reluctance sensors. My question is: does it
matter if the leads get reversed on either or both of the sensors? Say
I get the correct two wires going to each of the sensors, but I
reversed the polarity. Does that matter?
Thanks for the downloadable manual.
Brian Trubee
Brian
I searched a lot and came up with nothing for a reluctor connector.
They are the same keying as some injectors, BUT the injector
connectors will not fully engage to the point where the latch holds
them in.
Robert
Tracy recommends cutting off part of the housing around
the connector and soldering wires on to the pins.
Page 23.
This will work of course but there is a better
way. It is called a Molex socket.
No need to saw off part of the connector on the CAS.
They are made in at least two sizes.
The .093 is a bit big but the .063 works fine.
Just solder a wire to the socket outside the CAS
and install them with a pair of needle nose plier.
Then fill the cavity with RTV or Epoxy if you wish.
It worked for me.
Paul Lamar
According to Megasquirt data, it can matter if leads are reversed with
variable reluctance, because the edge of the signal is not square or
something:-[ . Variable reluctance will have a magnet built into the sensor.
John Burey
--
The Rotary Engine NewsLetter. Powered by Linux.
ACRE NL web site.
http://www.rotaryeng.net
Youtube key word PaulLamar2