Subject: starter cable size
From: rotaryeng
Date: 6/27/2013, 9:50 PM
To: AAA-rotaryeng



Hi Paul

Looking forward to seeing the development of the T compound.

Question:

I have a 1300mm 4.3 foot run from my PC680 battery to the Renesis
using an older model starter. Could I get away with 4GA cable or do I
need 2GA?

Thanks

Steve Izett

Go with the 4 Ga. Check the voltage on the starter when the engine is turning over.
If it is a least 10 volts and the engine starts your OK.  Starters draw 300 amps or so.
3 to 5 HP.

Going to larger cable will just increase the voltage on the starter by a  couple of tenths of a volt or so.

http://www.calculator.net/voltage-drop-calculator.html?material=copper&wiresize=0.2557&voltage=12&phase=dc&noofconductor=1&distance=4.3&distanceunit=feet&amperes=300&x=78&y=10