Paul,
I am working with a 2nd gen CAS and wondered why the calculated
frequency at a given RPM does not match what I am seeing on the
scope?
Maybe I am calculating it wrong; (RPM X 24teeth)/ 60 Thanks for any
help
Joe Berki
The 2nd gen CAS rotates at half e-shaft speed. So it is only 12 teeth
per revolution.
Paul Lamar
Paul,
E shaft is at 8000 rpm divide by 2 = 4000 rpm X 24 = 96000 / 60 =
1600 Hz = .625msec period.
I measured 3.15msec period = 2857 Hz,
I divided the eshaft rpm by 2 and spun the CAS to half of the eshaft
speed.
I measured the output with a scope and calculated freq as i/period.
What am I missing?
Joe Berki
Divide RPM by 60 for CPS (Hertz in the French system :))
Put all your units in the equation. Helps to keep track of what your
doing. Your math teacher may have been a liberal arts major :)
8000 RPM / 2 = 4000 RPM
4000 RPM x 24 teeth = 96000 PPS or teeth per second.
1 / 96000 PPS = 0.00001041666666666667 second for one tooth.
.01041 milli second period.
Are you sure you are looking at the lower sensor?
If so I may be out of adjustment. Not much of a gap there.
Paul Lamar
Paul, Sorry, 3.15 msec = 1/ .00315 = 3174 Hz
Joe Berki
Paul,
Does the CAS need to be calibrated?
If so how is it done?
Joe Berki
No but the gap is adjustable. My guess is somewhere
around .020 to .030.
Paul Lamar
If I remember correctly we used a .016" brass feeler gauge to set the
reluctor wheel to pick-up clearance... steel could help demagnetize the
wheel.
Barry Bordes
The Rotary Engine News Letter. Powered by Linux. ACRE NL web site.
http://www.rotaryeng.net <http://www.rotaryeng.net/>You Tube
http://tinyurl.com/beqqxas
Copyright 1998-2014 All world wide rights reserved.