Dan found room between the fuel tank and the side of the aircraft to
fit the wastes gate control cable in. It gave us more precise control
over the waste gate opening with a much longer lever.
Worked like a charm. The max boost was limited to about 15 to 20
inches. That is about 50 to 70 inches of HG.
So we said "lets see what happens if we make the 1.25 inch bypass
aperture smaller." We then tried a .8 inch diameter and the turbo ran
way. More eng RPM more boost more eng RPM more boost and so on.
Mathematically it is an exponential function. It started dragging my
4000 pound truck in park :-)
Dan jerked the throttle back.
We then tried a 1 inch aperture. It still ran away at RPM and high
boost.
This is at sea level of course once you get up to several thousand
feet things will change.
Here are some pictures.
We need to go back into the Motec and reset the mixture. Does anybody
on here know how to convert Motec mixture numbers like .7 or .8 to a
mixture ratio like 14 to one?
It starts as easy as my RX8. Smoke for a few seconds on start up but
that is normal for a turbo charger.
Paul Lamar
Is that 15 to 20 inches water, Hg or PSI? Should be Hg or PSI as Hg
would give the 70 inches water. I forget the conversion.
Dale Davies
I get confused some times. The Motec is a mishmash of measurement
systems.
Imagine calling a pressure with a persons name. That is why they
call a pressure pascal's in the metric system. REALLY STUPID!!!!!!
It is a force divided by an area for @#@## sakes. PSI or Kilograms
per square meter is intuitive.
I am surprised they don't call Miles Per Hour or Kilometers Per
Hour Napoleon's :-)
The linear measurements are OK with mm, meters, kilometers doing
away with inches, feet and miles.
All arbitrary measurements. However one could say micro, milli,
mega and giga inches.
The latest is converting a ratio to a decimal number. Really
stupid. Yes
14.7 is the ratio of air to
fuel that results in a complete change. Now we have .73 mixture.
We have boost in psi, inches of Hg (the aircraft engine standard)
pressure and heaven forbid microPascals.
30 inches of Hg is roughly atmospheric pressure at sea level. So is
15 psi. So you can see the conversion problem. It extends to pressure
measuring devices. Manometers are very low cost and very accurate
devices with inches of water and inches of Mercury (Hg). There are
absolute pressure gages and gage pressure gages. Inches of Hg is
absolute while boost in psi is gage pressure.
The metric system has thrown the engineering world into chaos. It
would have been better to keep furlongs per fortnight alone and forget
the metric system :-) My late great rocket scientist and experimental
aircraft designer friend, Vance Jaqua, was fond of saying we got to the
moon on inches.
After all Sir Isaac Newton was English. It is not for nothing that
they call it Newtonian Physics.
I can understand why nobody wants to study engineering any more. It
is taught in the silly metric system.
One goes into the lumber yard and sees 2 by 4's and nuts and bolts
in inches.
Paul Lamar
Hi Paul,
Both systems of measurement have their idiosyncrasies, it all depends
on what system you are used to (what you grew up with). I mean what
could be more stupid than the Fahrenheit temperature scale, water
boiling at 212 deg instead of 100 deg and freezing at 32 deg instead of
0. If you say (and I agree with you)it is stupid to use somebody's name
for a scale of some sort, it is no more stupid than using some English
kings foot measurement to be called a foot and divide it into 12 instead
of ten, (we have TEN toes and fingers) a yard is the length of his arm
etc, I shudder to think what the 6 inch measurement comes from. At least
in metric everything is in tens.
Chris Hoskins.
I agree on decimals. Micro, milli, mega and giga inches :-)
I think the inch was the distance from the King's thumb knuckle to
the end of his thumb :-)
Why water? Why not oil. After all they boiled the bad guys in oil
those days :-)
Something has to be a standard. I think the meter has something to
do with the diameter of the earth.
The strength difference between a 10 mm bolt and an 8 mm bolt is
enormous.
The 8 is something like 64% as strong as a 10 mm bolt. I have never
seen a 9 mm bolt.
Fraction of an inch bolts are much closer. The weight of a device
will be lighter
if fraction of an inch bolts are used and just strong enough is
chosen..
Paul Lamar
I seem to remember the source for the inch was one kings big toe length.
How you get twelve toes to a foot baffled crap out of me as a youngster.
I only have five. There was a kid had six.
Metric system does make sense in multiples of 10 to the next division.
Pascals and Newtons and bar are sort of confusing but just names. No
worse than the crazy imperial system. It is what many of us learned first.
English is another anomaly. All the crazy rules. I before E except after
C. But then there are special instances you just need to memorize.
Foreign, neighbor and sovereign. Then three words that sound the same
but spelled differently and mean totally different things. You just need
to know the context in the sentence before or after. Some of that still
messes my grey matter up.
Dale Davies
The Rotary Engine free News Letter. Powered by Linux. If you want
off the list PLEASE let me know and I will remove you. ACRE NL web
site.
http://www.rotaryeng.net You Tube
http://tinyurl.com/beqqxas
Copyright 1998-2017 All world wide rights reserved.